Need help?

NW ES

Illustration
Illustration
Application

Prefiltration in air handling units.

Application areas

  • Low pressure drop
  • Excellent dust retention capacity
  • Self-supporting pockets
  • Conical pockets designed for maximum performance
  • Easy installation
  • Tested for food contact according to CE 1935/2004
Certificates

General Characteristics

Filtration class according to ISO16890: 2016
Media: Nanowave
Final pressure drop according to EN 13053: initial pressure drop + 100 Pa or initial pressure drop x3 (whichever is smaller).
Maximum continuous service temperature: 80 °C
Relative humidity: 100% RH
Contact our expert
  • NW ES

    Illustration variation
  • ePM1 70% ISO16890 - (F7)

    • 592

    • Height B (mm)

      592

    • Depth C (mm)

      360

    • Pockets

      8

    • Surface (m2)

      3,4

    • Actual filter area (m2)

      8,5

    • Airflow (m3/h)/Delta P (Pa)

      3400 / 99

    • Energy consumption (kWh/year)*

      1495

    • Energy class**

      C

    • 490

    • Height B (mm)

      592

    • Depth C (mm)

      360

    • Pockets

      6

    • Surface (m2)

      2,6

    • Actual filter area (m2)

      6,5

    • Airflow (m3/h)/Delta P (Pa)

      2800 / 99

    • Energy consumption (kWh/year)*

    • Energy class**

    • 287

    • Height B (mm)

      592

    • Depth C (mm)

      360

    • Pockets

      4

    • Surface (m2)

      1,7

    • Actual filter area (m2)

      4,25

    • Airflow (m3/h)/Delta P (Pa)

      1700 / 99

    • Energy consumption (kWh/year)*

    • Energy class**

    • 592

    • Height B (mm)

      592

    • Depth C (mm)

      360

    • Pockets

      10

    • Surface (m2)

      4,3

    • Actual filter area (m2)

      10,75

    • Airflow (m3/h)/Delta P (Pa)

      3400 / 95

    • Energy consumption (kWh/year)*

      1335

    • Energy class**

      C

    • 490

    • Height B (mm)

      592

    • Depth C (mm)

      360

    • Pockets

      8

    • Surface (m2)

      3,4

    • Actual filter area (m2)

      8,5

    • Airflow (m3/h)/Delta P (Pa)

      2800 / 95

    • Energy consumption (kWh/year)*

    • Energy class**

    • 287

    • Height B (mm)

      592

    • Depth C (mm)

      360

    • Pockets

      5

    • Surface (m2)

      2,1

    • Actual filter area (m2)

      5,25

    • Airflow (m3/h)/Delta P (Pa)

      1700 / 95

    • Energy consumption (kWh/year)*

    • Energy class**

    • 592

    • Height B (mm)

      592

    • Depth C (mm)

      450

    • Pockets

      8

    • Surface (m2)

      4,3

    • Actual filter area (m2)

      10,75

    • Airflow (m3/h)/Delta P (Pa)

      3400 / 83

    • Energy consumption (kWh/year)*

      1183

    • Energy class**

      B

    • 490

    • Height B (mm)

      592

    • Depth C (mm)

      450

    • Pockets

      6

    • Surface (m2)

      3,2

    • Actual filter area (m2)

      8

    • Airflow (m3/h)/Delta P (Pa)

      2800 / 83

    • Energy consumption (kWh/year)*

    • Energy class**

    • 287

    • Height B (mm)

      592

    • Depth C (mm)

      450

    • Pockets

      3

    • Surface (m2)

      2,1

    • Actual filter area (m2)

      5,25

    • Airflow (m3/h)/Delta P (Pa)

      1700 / 83

    • Energy consumption (kWh/year)*

    • Energy class**

    • 592

    • Height B (mm)

      592

    • Depth C (mm)

      450

    • Pockets

      10

    • Surface (m2)

      5,3

    • Actual filter area (m2)

      13,25

    • Airflow (m3/h)/Delta P (Pa)

      3400 / 79

    • Energy consumption (kWh/year)*

      1050

    • Energy class**

      A

    • 490

    • Height B (mm)

      592

    • Depth C (mm)

      450

    • Pockets

      8

    • Surface (m2)

      4,3

    • Actual filter area (m2)

      10,75

    • Airflow (m3/h)/Delta P (Pa)

      2800 / 79

    • Energy consumption (kWh/year)*

    • Energy class**

    • 287

    • Height B (mm)

      592

    • Depth C (mm)

      450

    • Pockets

      5

    • Surface (m2)

      2,7

    • Actual filter area (m2)

      6,75

    • Airflow (m3/h)/Delta P (Pa)

      1700 / 79

    • Energy consumption (kWh/year)*

    • Energy class**

    • 592

    • Height B (mm)

      592

    • Depth C (mm)

      580

    • Pockets

      8

    • Surface (m2)

      5,5

    • Actual filter area (m2)

      13,75

    • Airflow (m3/h)/Delta P (Pa)

      3400 / 73

    • Energy consumption (kWh/year)*

      961

    • Energy class**

      A

    • 490

    • Height B (mm)

      592

    • Depth C (mm)

      580

    • Pockets

      6

    • Surface (m2)

      4,6

    • Actual filter area (m2)

      11,5

    • Airflow (m3/h)/Delta P (Pa)

      2800 / 73

    • Energy consumption (kWh/year)*

    • Energy class**

    • 287

    • Height B (mm)

      592

    • Depth C (mm)

      580

    • Pockets

      4

    • Surface (m2)

      2,75

    • Actual filter area (m2)

      6,9

    • Airflow (m3/h)/Delta P (Pa)

      1700 / 73

    • Energy consumption (kWh/year)*

    • Energy class**

    • 592

    • Height B (mm)

      592

    • Depth C (mm)

      580

    • Pockets

      10

    • Surface (m2)

      6,9

    • Actual filter area (m2)

      17,25

    • Airflow (m3/h)/Delta P (Pa)

      3400 / 68

    • Energy consumption (kWh/year)*

      827

    • Energy class**

      A+

    • 490

    • Height B (mm)

      592

    • Depth C (mm)

      580

    • Pockets

      8

    • Surface (m2)

      6

    • Actual filter area (m2)

      15

    • Airflow (m3/h)/Delta P (Pa)

      2800 / 68

    • Energy consumption (kWh/year)*

    • Energy class**

    • 287

    • Height B (mm)

      592

    • Depth C (mm)

      580

    • Pockets

      5

    • Surface (m2)

      3,5

    • Actual filter area (m2)

      8,75

    • Airflow (m3/h)/Delta P (Pa)

      1700 / 68

    • Energy consumption (kWh/year)*

    • Energy class**

  • ePM1 90% ISO16890 - (F9)

    • 592

    • Height B (mm)

      592

    • Depth C (mm)

      360

    • Pockets

      8

    • Surface (m2)

      3,4

    • Actual filter area (m2)

      8,5

    • Airflow (m3/h)/Delta P (Pa)

      3400 / 149

    • Energy consumption (kWh/year)*

      2172

    • Energy class**

      D

    • 490

    • Height B (mm)

      592

    • Depth C (mm)

      360

    • Pockets

      6

    • Surface (m2)

      26

    • Actual filter area (m2)

      6,5

    • Airflow (m3/h)/Delta P (Pa)

      2800 / 149

    • Energy consumption (kWh/year)*

    • Energy class**

    • 287

    • Height B (mm)

      592

    • Depth C (mm)

      360

    • Pockets

      4

    • Surface (m2)

      1,7

    • Actual filter area (m2)

      4,25

    • Airflow (m3/h)/Delta P (Pa)

      1700 / 149

    • Energy consumption (kWh/year)*

    • Energy class**

    • 592

    • Height B (mm)

      592

    • Depth C (mm)

      360

    • Pockets

      10

    • Surface (m2)

      4,3

    • Actual filter area (m2)

      10,75

    • Airflow (m3/h)/Delta P (Pa)

      3400 / 129

    • Energy consumption (kWh/year)*

      1797

    • Energy class**

      C

    • 490

    • Height B (mm)

      592

    • Depth C (mm)

      360

    • Pockets

      8

    • Surface (m2)

      3,4

    • Actual filter area (m2)

      8,5

    • Airflow (m3/h)/Delta P (Pa)

      2800 / 129

    • Energy consumption (kWh/year)*

    • Energy class**

    • 287

    • Height B (mm)

      592

    • Depth C (mm)

      360

    • Pockets

      5

    • Surface (m2)

      2,1

    • Actual filter area (m2)

      5,25

    • Airflow (m3/h)/Delta P (Pa)

      1700 / 129

    • Energy consumption (kWh/year)*

    • Energy class**

    • 592

    • Height B (mm)

      592

    • Depth C (mm)

      450

    • Pockets

      8

    • Surface (m2)

      4,3

    • Actual filter area (m2)

      10,75

    • Airflow (m3/h)/Delta P (Pa)

      3400 / 122

    • Energy consumption (kWh/year)*

      1706

    • Energy class**

      C

    • 490

    • Height B (mm)

      592

    • Depth C (mm)

      450

    • Pockets

      6

    • Surface (m2)

      3,2

    • Actual filter area (m2)

      8

    • Airflow (m3/h)/Delta P (Pa)

      2800 / 122

    • Energy consumption (kWh/year)*

    • Energy class**

    • 287

    • Height B (mm)

      592

    • Depth C (mm)

      450

    • Pockets

      3

    • Surface (m2)

      2,1

    • Actual filter area (m2)

      5,25

    • Airflow (m3/h)/Delta P (Pa)

      1700 / 122

    • Energy consumption (kWh/year)*

    • Energy class**

    • 592

    • Height B (mm)

      592

    • Depth C (mm)

      450

    • Pockets

      10

    • Surface (m2)

      5,3

    • Actual filter area (m2)

      13,25

    • Airflow (m3/h)/Delta P (Pa)

      3400 / 104

    • Energy consumption (kWh/year)*

      1389

    • Energy class**

      A

    • 490

    • Height B (mm)

      592

    • Depth C (mm)

      450

    • Pockets

      8

    • Surface (m2)

      4,3

    • Actual filter area (m2)

      10,75

    • Airflow (m3/h)/Delta P (Pa)

      2800 / 104

    • Energy consumption (kWh/year)*

    • Energy class**

    • 287

    • Height B (mm)

      592

    • Depth C (mm)

      450

    • Pockets

      5

    • Surface (m2)

      2,7

    • Actual filter area (m2)

      6,75

    • Airflow (m3/h)/Delta P (Pa)

      1700 / 104

    • Energy consumption (kWh/year)*

    • Energy class**

    • 592

    • Height B (mm)

      592

    • Depth C (mm)

      580

    • Pockets

      8

    • Surface (m2)

      5,5

    • Actual filter area (m2)

      13,75

    • Airflow (m3/h)/Delta P (Pa)

      3400 / 96

    • Energy consumption (kWh/year)*

      1250

    • Energy class**

      A

    • 490

    • Height B (mm)

      592

    • Depth C (mm)

      580

    • Pockets

      6

    • Surface (m2)

      4,6

    • Actual filter area (m2)

      11,5

    • Airflow (m3/h)/Delta P (Pa)

      2800 / 96

    • Energy consumption (kWh/year)*

    • Energy class**

    • 287

    • Height B (mm)

      592

    • Depth C (mm)

      580

    • Pockets

      4

    • Surface (m2)

      2,75

    • Actual filter area (m2)

      6,9

    • Airflow (m3/h)/Delta P (Pa)

      1700 / 96

    • Energy consumption (kWh/year)*

    • Energy class**

    • 592

    • Height B (mm)

      592

    • Depth C (mm)

      580

    • Pockets

      10

    • Surface (m2)

      6,9

    • Actual filter area (m2)

      17,25

    • Airflow (m3/h)/Delta P (Pa)

      3400 / 84

    • Energy consumption (kWh/year)*

      1044

    • Energy class**

      A+

    • 490

    • Height B (mm)

      592

    • Depth C (mm)

      580

    • Pockets

      8

    • Surface (m2)

      6

    • Actual filter area (m2)

      15

    • Airflow (m3/h)/Delta P (Pa)

      2800 / 84

    • Energy consumption (kWh/year)*

    • Energy class**

    • 287

    • Height B (mm)

      592

    • Depth C (mm)

      580

    • Pockets

      5

    • Surface (m2)

      3,5

    • Actual filter area (m2)

      8,75

    • Airflow (m3/h)/Delta P (Pa)

      1700 / 84

    • Energy consumption (kWh/year)*

    • Energy class**

* Energy consumption, kWh/year: calculated according to Eurovent Guideline 4/21-2018 | ** Energy class: according to Eurovent RS4/C/001-2019 | *** Energy class: according to Eurovent RS4/C/001-2015
Application areas

An air filtration system adapted to each sector

Illustration

Airports

Offer travelers a healthy transit and reduce the presence of particles in the air.

Discover all sectors
Illustration
TFM® Service

Choose TFM® and benefit from a comprehensive maintenance contract for air filtration.

Need clean air in your workplace? With the TFM® contract, you will benefit from high-performance air filters tailored to your needs, scalable services, and dedicated teams to advise you on the installation of new equipment.

Learn more about our service

Do you have any questions? Our team is here to help.

Our experts are available to answer all your questions.

Contact our expert
Illustration
Expert illustration

Hi, my name is Wannes Van Herck, how can I assist you?

Contact our expert