Need help?

RPV GT XL

Illustration
Illustration
Application

Filtration for air treatment centers equipped upstream with a pre-filter and preparatory filtration in "GTS" applications.

Application areas

  • Compact and economical
  • Large filter surface
  • High efficiency
  • Tested for food contact according to CE 1935/2004
  • Certified inert to microbial development (ISO 846-VDI 6022)
Certificates

General Characteristics

Filtration class according to standard 29461-1 : T9-T12
Media: mini-pleated fiberglass paper
Frame: polystyrene
Lut: polyurethane
Separators: hot-melt wire
Final pressure drop: 450 Pa
Recommended ECO final pressure drop: 250 Pa
Maximum continuous service temperature: 80°C
Relative humidity: 100%
Contact our expert
  • RPV GT XL

    Illustration variation
  • F9 - (T9)

    • 592

    • Description

      RPV98-6XL/X WR

    • Height B (mm)

      592

    • Depth C (mm)

      440

    • Surface (m2)

      32

    • Airflow (m3/h)/Delta P (Pa)

      3400 / 85

    • Airflow (m3/h)/Delta P (Pa)

      4250 / 125

  • E10 - (T10)

    • 592

    • Description

      RPV100-6XL/X WR

    • Height B (mm)

      592

    • Depth C (mm)

      440

    • Surface (m2)

      32

    • Airflow (m3/h)/Delta P (Pa)

      3400 / 137

    • Airflow (m3/h)/Delta P (Pa)

      42550 / 180

  • E11 - (T11)

    • 592

    • Description

      RPV110-6XL/X WR

    • Height B (mm)

      592

    • Depth C (mm)

      440

    • Surface (m2)

      32

    • Airflow (m3/h)/Delta P (Pa)

      3400 / 190

    • Airflow (m3/h)/Delta P (Pa)

      4250 / 250

  • E12 - (T12)

    • 592

    • Description

      RPV120-6XL/X WR

    • Height B (mm)

      592

    • Depth C (mm)

      440

    • Surface (m2)

      32

    • Airflow (m3/h)/Delta P (Pa)

      3400 / 220

    • Airflow (m3/h)/Delta P (Pa)

      4250 / 285

* Energy consumption, kWh/year: calculated according to Eurovent Guideline 4/21-2018 | ** Energy class: according to Eurovent RS4/C/001-2019 | *** Energy class: according to Eurovent RS4/C/001-2015
Application areas

An air filtration system adapted to each sector

Illustration

Gas Turbines

An adequate air filtration solution for your gas turbines.

Discover all sectors
Illustration
TFM® Service

Choose TFM® and benefit from a comprehensive maintenance contract for air filtration.

Need clean air in your workplace? With the TFM® contract, you will benefit from high-performance air filters tailored to your needs, scalable services, and dedicated teams to advise you on the installation of new equipment.

Learn more about our service

Do you have any questions? Our team is here to help.

Our experts are available to answer all your questions.

Contact our expert
Illustration
Expert illustration

Hello, my name is Jürgen Alexius. What can I do for you?

Contact our expert